Suitable for fixed installation for telecommunication installations in dry and damp locations, as well as in and under plaster, outdoors with fixed installation. These cables are suitable for intercom and extension, signal and measurement data transmission. Installation cables are not approved for underground installation.
The materials used are free from silicon and cadmium and free from varnish damaging sustances.
The materials used are free from silicon and cadmium and free from varnish damaging sustances.
Nominal voltage | Uo/U: 0/300 V |
Test voltage | 800 V |
Bending radius fixed (xD) | 15 |
Operating temperature fixed | -30°C bis 70°C |
Operating temperature mobile | -5°C bis 50°C |
Fire classes | Eca |
Standard | DIN VDE 0815, fire testing acc. to EN 60332-1-2 and 2-2 |
Standard CE | CE = The product is conformed with the EC Low-Voltage Directive 2014/35/EU. |
inner Conductor | bare copper, solid 0,6 mm / 0,8 mm |
core Insultation | Polyvinyl chloride (PVC) |
Core colour code | colored (VDE 0815) |
layer | cores to pairs, pairs twisted in layers and wrapping with plastic tape |
Overall shielding | kunststoffkaschierte Aluminiumfolie mit Beidraht |
Outer sheath material | Polyvinyl chloride (PVC) |
J-Y(St)Y
Art.Nr
Net amount
Metal surcharge
Total amount