Product images are symbolic photos

Product images are symbolic photos
This cable is suitable for track bound vehicles and trackless trolley buses as well as for installations in dry locations, in switchboards and distributors up to 1.000 V as a short circuit and earth fault proof cable.
For use in direct current operation (DC) : Uo/U: 2.7/5.4 kV
For use in direct current operation (DC) : Uo/U: 2.7/5.4 kV
Nominal voltage | Uo/U: 1800/3000 V |
Test voltage | 6 kV |
Bending radius fixed (xD) | 6 |
Operating temperature fixed | -40°C bis 90°C |
Operating temperature mobile | -25°C bis 90°C |
Short-circuit temperature | 250°C |
Short circuit duration | 5 sek. |
Fire classes | Eca |
Standard | DIN VDE 0250 part 602, DIN EN 60811-100 VDE 0473-811-100:2012-12 self-extinguishing and flame retardant acc. to DIN EN 60332-1-2, IEC 60332-1 |
Standard CE | CE = The product is conformed with the EC Low-Voltage Directive 2014/35/EU. |
inner Conductor | fine-stranded tinned copper acc. DIN VDE 0295 cl. 5 and IEC 60228 cl. 5 |
core Insultation | EPR rubber |
Outer sheath material | polychloroprene 5GM3 to DIN VDE 0207 Part 21 |
Constant Against | abrasion and oil resistant acc. to DIN VDE 0473 Teil 811-2-1, UV-and Ozon resistant |
NSGAFöu 1,8/3 kV
Art.Nr
Net amount
Metal surcharge
Total amount
Produkt wurde hinzugefügt