DE / EN / HU / CS / SK
product-img
Product images are symbolic photos
product-img
Product images are symbolic photos
Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burrial- or as underwater cable. Mainly used in South-European, Eastern and Arabian countries. Interference- free transmission of signals and pulses is assured by the high degree of screening.

The materials used are free from silicon and cadmium and free from varnish damaging sustances.

Nominal voltage Uo/U: 600/1000 V
Test voltage 4000 V
Bending radius fixed (xD) 5
Operating temperature fixed -40°C bis 70°C
Operating temperature mobile -5°C bis 70°C
Short-circuit temperature 150°C
Short circuit duration 5 sek.
Fire classes Eca
Standard Adapted to DIN VDE 0262/12.95 and DIN EN 50525-2-51 VDE 0285-525-2-51:2012-01,
self-extinguishing and flame retardant acc. to VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1
Standard CE CE = The product is conformed with the EC Low-Voltage Directive 2014/35/EU.
inner Conductor fine-stranded bare copper acc. DIN
VDE 0295 cl. 5 / IEC 60228 cl. 5
core Insultation special polyvinylchlorid compound
(PVC) TI2 to DIN VDE 0281 part 1
Core colour code black cores with continuous white
numbering according to DIN VDE 0293
green-yellow earth core in the outer
layer (3 cores and above)
layer cores stranded in layers with optimalbr>lay-length
inner Sheath Material special PVC inner sheath, TM2 to DIN
VDE 0281 part 1
Overall shielding braid shield copper tinned
Outer sheath material special PVC type TM2 to DIN VDE
0281 part 1
Constant Against extensively oil resistant
YSLYCY-JZ 0,6/1kV
Art.Nr

Net amount
Metal surcharge
Total amount