DE / EN / HU / CS / SK
product-img
Product images are symbolic photos
product-img
Product images are symbolic photos
These data control cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. LiYCY is well suited for use in areas subject to signal interference. The high level of screening reduces substantially the effects of electrical disturbances from parallel running wiring etc. The copper screening is also often used as an “earth“. The twisted pairs conform favourable cross-talk attenuation values.

The materials used are free from silicon and cadmium and free from varnish damaging sustances.

Nominal voltage Uo/U: 300/500 V
Test voltage 1200 V
Bending radius fixed (xD) 4
Operating temperature fixed -40°C bis 80°C
Operating temperature mobile -5°C bis 70°C
Fire classes Eca
Standard adapted to DIN VDE 0812,
self-extinguishing and flame retardant acc. to VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1
Standard CE CE = The product is conformed with the EC Low-Voltage Directive 2014/35/EU.
inner Conductor fine-stranded bare copper acc. DIN
VDE 0295 cl. 5 / IEC 60228 cl. 5
core Insultation Spezial Polyvinylchlorid (PVC) TI2 nach
DIN VDE 0207 Teil 4
Core colour code acc. to DIN 47100 with colour repe-
tition
layer cores stranded in pairs and pairsbr>stranded in layers with optimal lay-br>length
Overall shielding braid shield copper tinned
Outer sheath material special PVC outer sheath TM2, to DIN
VDE 0207 part 5
Constant Against extensively oil resistant
LiYCY (TP)
Art.Nr

Net amount
Metal surcharge
Total amount